The  BESS  was  verified  under  conditions  for  charging  and  discharging  to  prove  the  Simulink  model
                   functional. For charging the BESS was set to 75% SOC, which was lower than 80% SOC set point.


















                                                       BESS simulation for 75% SOC
                   With the PV Array and PEM system disabled and the grid isolated, the simulation was run and confirmed that
                   the battery was discharging as shown.



















                                                   BESS for 80% SOC and discharging to load

                   When optimized, the limitation on the electrolyser was the highest attainable stack efficiency attained was
                   59% based on the 776V DC bus operation voltage as required. A higher efficiency would have been achieved
                   at lower operating voltage. The temperature and irradiance table was also modified as shown to simulate
                   night time hours by values being set to zero (0) for the next 13 hours of simulations.