Diesel Generator                                       exhaust gas recirculation (EGR) facility was added as the
        To verify the results of basic studies and experiments, the   second stage of construction, full-fledged operation has
        world’s  largest  1250  kW  DME  diesel  power  generation   been conducted since October, 2005.
        system  was  constructed  in  JFE  Engineering’s  Tsurumi   It can be confirmed that the combustion performance of
        Works, Yokohama, Japan.                                DME is as good as oil fuel from the results of combustion
        The diesel engine is based on Daihatsu 6DK-26, one of   analysis. Thermal efficiency is also of same level as oil.
        their  proven  products.  It  is  a  medium-speed  6-cylinder   Furthermore, concerning exhaust NOx, the most important
        engine equipped with jerk type injection pumps for each   development task, fine results far beyond the target were
        cylinder.                                              achieved; 1/10 to 1/30 of that of the oil powered engine.
        The extent of modification was relatively small, so it would  Through this MW-class DME diesel development project,
        be expected that existing oil-fueled engines can be easily  it has been demonstrated that DME has the practical
        converted to DME-fueled.                               potential as an alternative fuel for diesel engines and
        In  October,  2004,  construction  of  the  demonstration   for eco-friendly generation systems.
        plant was finished and its trial operation started. After the

























        DME as Diesel substitute for power generation in  〜Diesel oil price in Caribbean are higher than DME.
        the Caribbean                                          DME  is  more  suitable  for  dispersed  small  diesel
        The electric utility industry requires cheaper fuel. But,   electric power generation (5MW or less).
        global environment counter measure is also important   Since existing LPG tanker with very minor modifications
        in order to continue a electric utility industry.      can  be  utilized  for  transporting  DME,  additional
        Best  energy  for  global  environment  (CO2  emission   investment  for  logistics  would  “ONLY”  be  for  the
        per calorie) are hereinafter;                          receiving  tank  and  associated  facilities  at  customer
        Renewable > NG > LPG = DME > Diesel > HFO-C            site.
        > Coal
        0 85 100 113 119 150                                   BIBLIOGRAPHY
        But, the CAPEX for the renewable energy or NG (LNG)  〜 Basu, A., Gradassi, M., Sills, R., Fleisch, T., & Puri,
        is very high and also renewable energy has low power  R. (2001). Use of DME as a Gas Turbine Fuel. ASME
        generation efficiency (unstable power generation).     Turbo-Expo. New Orleans.
        By comparing Diesel power generation, DME has the  〜 “DME Handbook” edited by Japan DME Forum and
        advantage for the power generation view.               published by Ohmsha, Ltd. 2006. Printed in Japan
        〜The CO2 emission of DME is lower than Diesel.         〜  “DME  Handbook  Supplement”  edited  by  Japan
        〜The Capex of a DME power generator is equivalent  DME Forum and published by Ohmsha, Ltd. 2011.
        to a diesel power generator.                           Printed in Japan